2000L/H RO Water Treatment System High Flow with Anti-Scalant Injection | Skid-Mounted Reverse Osmosis Machine for Industrial Application

FRO-218-2T-3

✔ Capacity: 2000 LPH
✔ Voltage: 380V
✔ Power: 3.75kW
✔ 6-Stage Filtration
✔ Plug & Play Design

⚡ High Flow with 8040 Membranes

2000L/H (48,000 GPD) output. Two ULP21-8040 large-area membranes. Desalination rate ≥97%. 380V/3.75KW.

🧪 Chemical Dosing System

Built-in dosing tank + dosing pump. Anti-scalant injection prevents membrane fouling. Extends membrane life.

🔧 Complete 3-Stage Treatment

Sand filter + Carbon filter + Cartridge filter + Dosing. Full protection for challenging feed water.

Product Short Description

Industrial capacity. Anti-scaling protection. Fewer components.

The 2000L/H RO system features sand filter, carbon filter, precision filter, and chemical dosing system — essential pre-treatment plus anti-scalant injection for challenging feed water. Two ULP21-8040 large-area membranes deliver 2000L/H (48,000 GPD) with fewer components than 4040 arrays. Perfect for large factories, industrial facilities, and commercial water plants.


Product Highlights

🧱 Complete 3-Stage Pre-treatment⚡ High Flow 8040 Dual Membranes
Sand filter + Carbon filter + Cartridge filter. Essential protection for tap water and well water.Two ULP21-8040 large-area membranes. 2000L/H output. Desalination rate ≥97%. 380V/3.75KW.
🧪 Chemical Dosing System🔌 Plug & Play
Dosing tank + dosing pump for anti-scalant injection. Prevents membrane scaling, extends membrane life.Pre-assembled on steel frame. Connect water and power. Start within 4 hours.
🏭 Industrial Grade✅ CE Certified
Heavy-duty steel frame. FRP tanks with auto valves. Built for 24/7 continuous operation.1-year warranty. Factory direct from China. OEM customization available.

Applications


Applications

ApplicationDescription
🏭 Large FactoryProcess water, cleaning water, boiler feed water
🏨 Large HotelGuest drinking water, kitchen water, laundry, pool
🏥 HospitalMedical pure water, instrument cleaning
🏘️ Large CommunityCentralized water supply for large communities
🥤 Beverage PlantProduction water for drinks
💧 Commercial Water PlantBottled water, bagged water production

Filtration Process

Raw Water → Sand Filter → Carbon Filter → Anti-Scalant Dosing → Cartridge Filter → High Pressure Pump → RO Membranes (8040×2) → Pure Water
StageComponentFunction
1Sand FilterRemoves sediment, rust, suspended solids
2Carbon FilterRemoves chlorine, odor, organic matter
3Dosing SystemInjects anti-scalant to prevent membrane scaling
4Cartridge Filter5μm fine filtration, protects RO membranes
5RO Membranes (8040×2)Removes up to 99% of dissolved salts, bacteria, viruses

Technical Specifications

ParameterValue
ModelFRO-218-2T-3D
TypeSkid-Mounted RO System (3 Tanks with Dosing)
Flow Rate2000 L/H (≈ 48,000 GPD)
Desalination Rate≥97%
Recovery Rate50-75% (Adjustable)
MembraneULP21-8040 × 2
Single Membrane Area37.2 m²
Total Membrane Area74.4 m²
Tank ConfigurationSand Filter + Carbon Filter + Cartridge Filter (3 tanks)
Tank MaterialFRP (Fiberglass Reinforced Plastic)
Pre-treatmentSand + Carbon + Cartridge
Dosing SystemDosing tank + Dosing pump (for anti-scalant)
Voltage380V / 50Hz (220V/60Hz optional)
Power3.75 KW
FrameSteel, Skid-Mounted
Dimensions2500×800×1700 mm
Weight480 kg
Feed Water SourceTap water, well water, groundwater (TDS ≤ 2000 ppm)
Warranty1 Year
CertificationCE

What’s Included in the System?

ComponentQty
Sand Filter (FRP with auto valve)1
Carbon Filter (FRP with auto valve)1
Cartridge Filter (20 inch)1
Dosing Tank (PE)1
Dosing Pump1
RO Housing (FRP / SS) for 80402
RO Membrane (ULP21-8040)2
High Pressure Pump (3.75KW, 380V)1
Steel Frame (Skid-Mounted)1
PLC Control Panel1
Piping & Fittings1 set
Pressure Gauges & Flow Meters1 set

Note: Raw water tank and pure water tank are not included. They can be purchased separately.

8040 Membrane Advantage

2 x 8040 vs 8 x 4040 Comparison

Comparison8 x 4040 System2 x 8040 System (This Model)
Number of membranes8 pieces2 pieces
Total membrane area57.6 m²74.4 m² (29% more)
Membrane housings82
Piping connectionsManyFewer
Leak riskHigherLower
MaintenanceMore complexSimpler
Installation timeLongerShorter
Floor spaceLargerSmaller
Component countHighLow

Advantage: Fewer components means less maintenance, lower leak risk, easier installation, and larger total membrane area.


Chemical Dosing System: Why It Matters

The Problem

High scaling potential water (high silica, high hardness, high TDS) causes:

  • ❌ Scale buildup on RO membranes
  • ❌ Reduced water output
  • ❌ Increased pressure drop
  • ❌ Frequent chemical cleaning
  • ❌ Shortened membrane life

The Solution

Our system includes a chemical dosing system:

FeatureBenefit
Anti-scalant injectionPrevents scale formation on membrane surface
Adjustable dosing rateCustomizable for different water qualities
Dosing tank + pump completeReady to use, no additional components needed

Result: Extended membrane life · Reduced cleaning frequency · Stable operation


When to Choose Dosing System vs Softener

Water CharacteristicRecommended Solution
High hardness (Ca²⁺, Mg²⁺)Softener
High silica, high TDS, complex scaling potentialChemical Dosing System
Limited space, lower budgetChemical Dosing System
Both hardness and scaling potentialSoftener + Dosing
Want fewer componentsChemical Dosing System

This system includes a chemical dosing system — ideal for challenging feed water where a softener is not sufficient or practical, while using only 2 x 8040 membranes for simplicity.

Key Features

Feature 1: 2000L/H Industrial High Flow

  • 48,000 GPD daily output
  • Suitable for 4,000-5,000 people
  • Perfect for large factories, industrial facilities, hospitals, and commercial water plants

Feature 2: 2 x ULP21-8040 Large-Area Membranes

  • Two 8040 membranes in parallel
  • Total membrane area: 74.4 m² (29% more than 8 x 4040)
  • Desalination rate ≥97%
  • Low pressure operation (8-12 bar), energy saving
  • 2000L/H stable output

Feature 3: Chemical Dosing System

  • Prevents membrane scaling
  • Extends membrane cleaning interval
  • Reduces maintenance cost
  • Adjustable dosing rate

Feature 4: 3-Stage Pre-treatment

TankFunction
Sand FilterRemoves sediment, suspended solids
Carbon FilterRemoves chlorine, odor, organics
Cartridge Filter5μm fine filtration

Feature 5: Industrial Grade Construction

  • Heavy-duty steel frame — 480kg robust design
  • FRP tanks — corrosion-resistant, durable
  • Designed for 24/7 continuous industrial operation

Feature 6: PLC Auto Control

  • One-key start
  • Auto flush
  • Low pressure protection
  • Fault alarm display

8040 vs 4040 Detailed Comparison

Parameter8 x 4040 System2 x 8040 System (This Model)
Number of membranes82
Single membrane area7.2 m²37.2 m²
Total membrane area57.6 m²74.4 m²
Membrane housings needed82
Inter-connecting pipingComplexSimple
O-rings / seals16+4
Potential leak pointsManyFew
Installation time1 day2-3 hours
Spare parts inventoryHighLow
Maintenance complexityHighLow

FAQ

1. What is the daily output?
2000 L/H equals approximately 48,000 gallons per day (about 48 tons), enough for 4,000-5,000 people.

2. What is the advantage of 8040 membranes over 4040?
Two 8040 membranes provide 74.4 m² of membrane area — 29% more than eight 4040 membranes (57.6 m²). Fewer components (2 housings vs 8), less piping, lower leak risk, and easier maintenance.

3. What is the chemical dosing system for?
It injects anti-scalant into the feed water before the RO membranes. This prevents scale formation, extends membrane life, and reduces cleaning frequency.

4. Do I need to buy the chemical separately?
Yes. Anti-scalant is not included. We can recommend suitable products based on your water quality.

5. How often do I need to refill the dosing tank?
Depending on your water flow and dosing rate, a 40L tank typically lasts 2-4 weeks. We can calculate exact consumption based on your operating hours.

6. What is the difference between this and the softener model?
Softener removes hardness ions (Ca²⁺, Mg²⁺). Dosing system injects anti-scalant to prevent scale. For high silica or complex water, dosing is more effective. For very high hardness, a softener may still be needed.

7. What voltage is required?
Standard 380V / 50Hz (3-phase). 220V / 60Hz is available upon request.

8. How long does installation take?
About 4 hours. The system comes pre-assembled — just connect water inlet, drain, and power.

9. What is the MOQ?
1 set. OEM customization available for bulk orders.

Why Buy From Us?

✅ Factory Direct✅ CE Certified✅ 1-Year Warranty
No middleman. Better price.Internationally certified.Peace of mind.
✅ OEM Available✅ 24/7 Support✅ Global Shipping
Custom logo, color, voltage.We’re here to help.Delivered worldwide.

GET IN TOUCH

Schedule a Visit

Scroll to Top