
⚡ High Flow with 8040 Membranes
2000L/H (48,000 GPD) output. Two ULP21-8040 large-area membranes. Desalination rate ≥97%. 380V/3.75KW.
🧪 Chemical Dosing System
Built-in dosing tank + dosing pump. Anti-scalant injection prevents membrane fouling. Extends membrane life.
🔧 Complete 3-Stage Treatment
Sand filter + Carbon filter + Cartridge filter + Dosing. Full protection for challenging feed water.
Product Short Description
Industrial capacity. Anti-scaling protection. Fewer components.
The 2000L/H RO system features sand filter, carbon filter, precision filter, and chemical dosing system — essential pre-treatment plus anti-scalant injection for challenging feed water. Two ULP21-8040 large-area membranes deliver 2000L/H (48,000 GPD) with fewer components than 4040 arrays. Perfect for large factories, industrial facilities, and commercial water plants.
Product Highlights
| 🧱 Complete 3-Stage Pre-treatment | ⚡ High Flow 8040 Dual Membranes |
|---|---|
| Sand filter + Carbon filter + Cartridge filter. Essential protection for tap water and well water. | Two ULP21-8040 large-area membranes. 2000L/H output. Desalination rate ≥97%. 380V/3.75KW. |
| 🧪 Chemical Dosing System | 🔌 Plug & Play |
|---|---|
| Dosing tank + dosing pump for anti-scalant injection. Prevents membrane scaling, extends membrane life. | Pre-assembled on steel frame. Connect water and power. Start within 4 hours. |
| 🏭 Industrial Grade | ✅ CE Certified |
|---|---|
| Heavy-duty steel frame. FRP tanks with auto valves. Built for 24/7 continuous operation. | 1-year warranty. Factory direct from China. OEM customization available. |
Applications



Applications
| Application | Description |
|---|---|
| 🏭 Large Factory | Process water, cleaning water, boiler feed water |
| 🏨 Large Hotel | Guest drinking water, kitchen water, laundry, pool |
| 🏥 Hospital | Medical pure water, instrument cleaning |
| 🏘️ Large Community | Centralized water supply for large communities |
| 🥤 Beverage Plant | Production water for drinks |
| 💧 Commercial Water Plant | Bottled water, bagged water production |
Filtration Process
Raw Water → Sand Filter → Carbon Filter → Anti-Scalant Dosing → Cartridge Filter → High Pressure Pump → RO Membranes (8040×2) → Pure Water

| Stage | Component | Function |
|---|---|---|
| 1 | Sand Filter | Removes sediment, rust, suspended solids |
| 2 | Carbon Filter | Removes chlorine, odor, organic matter |
| 3 | Dosing System | Injects anti-scalant to prevent membrane scaling |
| 4 | Cartridge Filter | 5μm fine filtration, protects RO membranes |
| 5 | RO Membranes (8040×2) | Removes up to 99% of dissolved salts, bacteria, viruses |
Technical Specifications
| Parameter | Value |
|---|---|
| Model | FRO-218-2T-3D |
| Type | Skid-Mounted RO System (3 Tanks with Dosing) |
| Flow Rate | 2000 L/H (≈ 48,000 GPD) |
| Desalination Rate | ≥97% |
| Recovery Rate | 50-75% (Adjustable) |
| Membrane | ULP21-8040 × 2 |
| Single Membrane Area | 37.2 m² |
| Total Membrane Area | 74.4 m² |
| Tank Configuration | Sand Filter + Carbon Filter + Cartridge Filter (3 tanks) |
| Tank Material | FRP (Fiberglass Reinforced Plastic) |
| Pre-treatment | Sand + Carbon + Cartridge |
| Dosing System | Dosing tank + Dosing pump (for anti-scalant) |
| Voltage | 380V / 50Hz (220V/60Hz optional) |
| Power | 3.75 KW |
| Frame | Steel, Skid-Mounted |
| Dimensions | 2500×800×1700 mm |
| Weight | 480 kg |
| Feed Water Source | Tap water, well water, groundwater (TDS ≤ 2000 ppm) |
| Warranty | 1 Year |
| Certification | CE |
What’s Included in the System?
| Component | Qty |
|---|---|
| Sand Filter (FRP with auto valve) | 1 |
| Carbon Filter (FRP with auto valve) | 1 |
| Cartridge Filter (20 inch) | 1 |
| Dosing Tank (PE) | 1 |
| Dosing Pump | 1 |
| RO Housing (FRP / SS) for 8040 | 2 |
| RO Membrane (ULP21-8040) | 2 |
| High Pressure Pump (3.75KW, 380V) | 1 |
| Steel Frame (Skid-Mounted) | 1 |
| PLC Control Panel | 1 |
| Piping & Fittings | 1 set |
| Pressure Gauges & Flow Meters | 1 set |
Note: Raw water tank and pure water tank are not included. They can be purchased separately.
8040 Membrane Advantage
2 x 8040 vs 8 x 4040 Comparison
| Comparison | 8 x 4040 System | 2 x 8040 System (This Model) |
|---|---|---|
| Number of membranes | 8 pieces | 2 pieces |
| Total membrane area | 57.6 m² | 74.4 m² (29% more) |
| Membrane housings | 8 | 2 |
| Piping connections | Many | Fewer |
| Leak risk | Higher | Lower |
| Maintenance | More complex | Simpler |
| Installation time | Longer | Shorter |
| Floor space | Larger | Smaller |
| Component count | High | Low |
Advantage: Fewer components means less maintenance, lower leak risk, easier installation, and larger total membrane area.
Chemical Dosing System: Why It Matters
The Problem
High scaling potential water (high silica, high hardness, high TDS) causes:
- ❌ Scale buildup on RO membranes
- ❌ Reduced water output
- ❌ Increased pressure drop
- ❌ Frequent chemical cleaning
- ❌ Shortened membrane life
The Solution
Our system includes a chemical dosing system:
| Feature | Benefit |
|---|---|
| Anti-scalant injection | Prevents scale formation on membrane surface |
| Adjustable dosing rate | Customizable for different water qualities |
| Dosing tank + pump complete | Ready to use, no additional components needed |
Result: Extended membrane life · Reduced cleaning frequency · Stable operation
When to Choose Dosing System vs Softener
| Water Characteristic | Recommended Solution |
|---|---|
| High hardness (Ca²⁺, Mg²⁺) | Softener |
| High silica, high TDS, complex scaling potential | Chemical Dosing System |
| Limited space, lower budget | Chemical Dosing System |
| Both hardness and scaling potential | Softener + Dosing |
| Want fewer components | Chemical Dosing System |
This system includes a chemical dosing system — ideal for challenging feed water where a softener is not sufficient or practical, while using only 2 x 8040 membranes for simplicity.
Key Features
Feature 1: 2000L/H Industrial High Flow
- 48,000 GPD daily output
- Suitable for 4,000-5,000 people
- Perfect for large factories, industrial facilities, hospitals, and commercial water plants
Feature 2: 2 x ULP21-8040 Large-Area Membranes
- Two 8040 membranes in parallel
- Total membrane area: 74.4 m² (29% more than 8 x 4040)
- Desalination rate ≥97%
- Low pressure operation (8-12 bar), energy saving
- 2000L/H stable output
Feature 3: Chemical Dosing System
- Prevents membrane scaling
- Extends membrane cleaning interval
- Reduces maintenance cost
- Adjustable dosing rate
Feature 4: 3-Stage Pre-treatment
| Tank | Function |
|---|---|
| Sand Filter | Removes sediment, suspended solids |
| Carbon Filter | Removes chlorine, odor, organics |
| Cartridge Filter | 5μm fine filtration |
Feature 5: Industrial Grade Construction
- Heavy-duty steel frame — 480kg robust design
- FRP tanks — corrosion-resistant, durable
- Designed for 24/7 continuous industrial operation
Feature 6: PLC Auto Control
- One-key start
- Auto flush
- Low pressure protection
- Fault alarm display
8040 vs 4040 Detailed Comparison
| Parameter | 8 x 4040 System | 2 x 8040 System (This Model) |
|---|---|---|
| Number of membranes | 8 | 2 |
| Single membrane area | 7.2 m² | 37.2 m² |
| Total membrane area | 57.6 m² | 74.4 m² |
| Membrane housings needed | 8 | 2 |
| Inter-connecting piping | Complex | Simple |
| O-rings / seals | 16+ | 4 |
| Potential leak points | Many | Few |
| Installation time | 1 day | 2-3 hours |
| Spare parts inventory | High | Low |
| Maintenance complexity | High | Low |
FAQ
1. What is the daily output?
2000 L/H equals approximately 48,000 gallons per day (about 48 tons), enough for 4,000-5,000 people.
2. What is the advantage of 8040 membranes over 4040?
Two 8040 membranes provide 74.4 m² of membrane area — 29% more than eight 4040 membranes (57.6 m²). Fewer components (2 housings vs 8), less piping, lower leak risk, and easier maintenance.
3. What is the chemical dosing system for?
It injects anti-scalant into the feed water before the RO membranes. This prevents scale formation, extends membrane life, and reduces cleaning frequency.
4. Do I need to buy the chemical separately?
Yes. Anti-scalant is not included. We can recommend suitable products based on your water quality.
5. How often do I need to refill the dosing tank?
Depending on your water flow and dosing rate, a 40L tank typically lasts 2-4 weeks. We can calculate exact consumption based on your operating hours.
6. What is the difference between this and the softener model?
Softener removes hardness ions (Ca²⁺, Mg²⁺). Dosing system injects anti-scalant to prevent scale. For high silica or complex water, dosing is more effective. For very high hardness, a softener may still be needed.
7. What voltage is required?
Standard 380V / 50Hz (3-phase). 220V / 60Hz is available upon request.
8. How long does installation take?
About 4 hours. The system comes pre-assembled — just connect water inlet, drain, and power.
9. What is the MOQ?
1 set. OEM customization available for bulk orders.
Why Buy From Us?
| ✅ Factory Direct | ✅ CE Certified | ✅ 1-Year Warranty |
|---|---|---|
| No middleman. Better price. | Internationally certified. | Peace of mind. |
| ✅ OEM Available | ✅ 24/7 Support | ✅ Global Shipping |
| Custom logo, color, voltage. | We’re here to help. | Delivered worldwide. |
GET IN TOUCH
