3000L/H RO Water Treatment System with Softener & Chemical Dosing
5-Stage Complete Pre-treatment for High Hardness Challenging Water | Skid-Mounted Reverse Osmosis Machine for Industrial Application

FRO-218-3T-3SD
✔ Capacity: 3000 LPH
✔ Voltage: 380V
✔ Power: 4.5kW
✔ 6-Stage Filtration
✔ Plug & Play Design

⚡ High Flow Industrial Capacity

3000L/H (72,000 GPD) output. Three ULP21-8040 large-area membranes. Desalination rate ≥97%. 380V/4.5KW.

🛡️ Softener + Dosing Dual Protection

Softener removes Ca²⁺, Mg²⁺. Dosing system injects anti-scalant. Double protection against membrane scaling.

🔧 Complete 5-Stage Treatment

Sand filter + Carbon filter + Softener + Dosing + Cartridge filter. Maximum protection for the most challenging feed water.

Product Short Description

Maximum protection. Industrial capacity. Uncompromised reliability.

The 3000L/H 5-Stage RO system features sand filter, carbon filter, softener (resin tank for calcium/magnesium removal), chemical dosing system (anti-scalant injection), and precision filter — the most complete pre-treatment for high hardness, high scaling potential water. Three ULP21-8040 large-area membranes deliver 3000L/H (72,000 GPD) with fewer components. Perfect for large factories, industrial facilities, beverage plants, and commercial water production with the most challenging feed water conditions.


Product Highlights

🧱 Complete 5-Stage Pre-treatment⚡ High Flow 8040 Triple Membranes
Sand filter + Carbon filter + Softener + Dosing + Cartridge filter. Maximum protection for high hardness, high scaling water.Three ULP21-8040 large-area membranes. 3000L/H output. Desalination rate ≥97%. 380V/4.5KW.
🛡️ Softener + Dosing Dual Protection🔌 Plug & Play
Softener removes calcium and magnesium. Dosing injects anti-scalant. Double protection extends membrane life significantly.Pre-assembled on steel frame. Connect water and power. Start within 4-6 hours.
🏭 Industrial Grade✅ CE Certified
Heavy-duty steel frame. FRP tanks with auto valves. Built for 24/7 continuous operation.1-year warranty. Factory direct from China. OEM customization available.

Applications

ApplicationDescription
🏭 Large FactoryProcess water, cleaning water, boiler feed water
🏭 Beverage PlantProduction water for soft drinks, juices, beer
🏨 Large HotelGuest drinking water, kitchen water, laundry, pool
🏥 Large HospitalMedical pure water, instrument cleaning, dialysis
🏘️ Large CommunityCentralized water supply for large communities
💧 Commercial Water PlantBottled water, bagged water production
🏭 Industrial ProcessCooling tower makeup, boiler feed water

Filtration Process

Raw Water → Sand Filter → Carbon Filter → Softener (Resin Tank) → Anti-Scalant Dosing → Cartridge Filter → High Pressure Pump → RO Membranes (8040×3) → Pure Water
StageComponentFunction
1Sand FilterRemoves sediment, rust, suspended solids
2Carbon FilterRemoves chlorine, odor, organic matter
3Dosing SystemInjects anti-scalant to prevent membrane scaling
4Cartridge Filter5μm fine filtration, protects RO membranes
5RO Membranes (8040×3)Removes up to 99% of dissolved salts, bacteria, viruses

Technical Specifications

ParameterValue
ModelFRO-218-3T-3SD
TypeSkid-Mounted RO System (5-Stage with Softener + Dosing)
Flow Rate3000 L/H (≈ 72,000 GPD)
Desalination Rate≥97%
Recovery Rate50-75% (Adjustable)
MembraneULP21-8040 × 3
Single Membrane Area37.2 m²
Total Membrane Area111.6 m²
Tank ConfigurationSand Filter + Carbon Filter + Softener + Cartridge Filter (4 tanks) + Dosing System
Tank MaterialFRP (Fiberglass Reinforced Plastic)
Machine Dimensions1900×800×1740 mm
Tank Dimensions2000×550×2100 mm (each)
Pre-treatmentSand + Carbon + Softener + Dosing + Cartridge
Softener Resin TypeFood grade strong acid cation exchange resin
Softener Resin Amount150L (for 3000L/H system)
RegenerationManual / Automatic (with brine tank)
Outlet Hardness≤ 50 mg/L (raw water hardness ≤ 400 mg/L)
Dosing SystemDosing tank + Dosing pump (anti-scalant injection)
Dosing Tank Capacity100L (standard)
Dosing Pump Capacity1-5 L/H (adjustable)
Voltage380V / 50Hz (220V/60Hz optional)
Power4.5 KW
FrameSteel, Skid-Mounted
Weight880 kg
Feed Water SourceWell water, groundwater, borehole water (high hardness, high scaling potential)
Max Feed Hardness≤ 400 mg/L (softened to ≤ 50 mg/L)
Max Feed TDS≤ 2000 ppm
Warranty1 Year
CertificationCE

What’s Included in the System?

ComponentQty
Sand Filter (FRP with auto valve)1
Carbon Filter (FRP with auto valve)1
Cartridge Filter (20 inch)1
Dosing Tank (PE)1
Dosing Pump1
RO Housing (FRP / SS) for 80403
RO Membrane (ULP21-8040)3
High Pressure Pump (4.5KW, 380V)1
Steel Frame (Skid-Mounted)1
PLC Control Panel1
Piping & Fittings1 set
Pressure Gauges & Flow Meters1 set

Note: Raw water tank and pure water tank are not included. They can be purchased separately.

Chemical Dosing System: Why It Matters

The Problem

High scaling potential water (high silica, high hardness, high TDS) causes:

  • ❌ Scale buildup on RO membranes
  • ❌ Reduced water output
  • ❌ Increased pressure drop
  • ❌ Frequent chemical cleaning
  • ❌ Shortened membrane life

The Solution

Our system includes a chemical dosing system:

FeatureBenefit
Anti-scalant injectionPrevents scale formation on membrane surface
Adjustable dosing rateCustomizable for different water qualities
Dosing tank + pump completeReady to use, no additional components needed

Result: Extended membrane life · Reduced cleaning frequency · Stable operation


When to Choose Dosing System vs Softener

Water CharacteristicRecommended Solution
High hardness (Ca²⁺, Mg²⁺)Softener
High silica, high TDS, complex scaling potentialChemical Dosing System
Limited space, lower budgetChemical Dosing System
Both hardness and scaling potentialSoftener + Dosing
Want fewer componentsChemical Dosing System

This system includes a chemical dosing system — ideal for challenging feed water where a softener is not sufficient or practical, while using only 3 x 8040 membranes for simplicity and high flow.


Key Features

Feature 1: 3000L/H High Capacity Industrial Flow

  • 72,000 GPD daily output
  • Suitable for 6,000-8,000 people
  • Perfect for large factories, industrial facilities, beverage plants, and commercial water production

Feature 2: 3 x ULP21-8040 Large-Area Membranes

  • Three 8040 membranes in parallel
  • Total membrane area: 111.6 m² (29% more than 12 x 4040)
  • Desalination rate ≥97%
  • Low pressure operation (8-12 bar), energy saving
  • 3000L/H stable output

Feature 3: Chemical Dosing System

  • Prevents membrane scaling
  • Extends membrane cleaning interval
  • Reduces maintenance cost
  • Adjustable dosing rate

Feature 4: 3-Stage Pre-treatment

TankFunction
Sand FilterRemoves sediment, suspended solids
Carbon FilterRemoves chlorine, odor, organics
Cartridge Filter5μm fine filtration

Feature 5: Industrial Grade Construction

  • Heavy-duty steel frame — 700kg robust design
  • FRP tanks — corrosion-resistant, durable
  • Separate tank dimensions: 1450×550×2020 mm each
  • Designed for 24/7 continuous industrial operation

Feature 6: PLC Auto Control

  • One-key start
  • Auto flush
  • Low pressure protection
  • Fault alarm display

8040 vs 4040 Detailed Comparison

Parameter12 x 4040 System3 x 8040 System (This Model)
Number of membranes123
Single membrane area7.2 m²37.2 m²
Total membrane area86.4 m²111.6 m²
Membrane housings needed123
Inter-connecting pipingVery complexSimple
O-rings / seals24+6
Potential leak pointsManyFew
Installation time2-3 days4-6 hours
Spare parts inventoryHighLow
Maintenance complexityVery highLow
Floor space requiredLargeCompact

FAQ

1. What is the daily output?
3000 L/H equals approximately 72,000 gallons per day (about 72 tons), enough for 6,000-8,000 people.

2. What is the advantage of 8040 membranes over 4040?
Three 8040 membranes provide 111.6 m² of membrane area — 29% more than twelve 4040 membranes (86.4 m²). Fewer components (3 housings vs 12), less piping, lower leak risk, and much easier maintenance.

3. What is the chemical dosing system for?
It injects anti-scalant into the feed water before the RO membranes. This prevents scale formation, extends membrane life, and reduces cleaning frequency.

4. Do I need to buy the chemical separately?
Yes. Anti-scalant is not included. We can recommend suitable products based on your water quality.

5. How often do I need to refill the dosing tank?
Depending on your water flow and dosing rate, a 40L tank typically lasts 2-4 weeks. For 3000L/H system, we recommend the 100L tank for longer operation between refills.

6. What is the difference between this and a softener system?
Softener removes hardness ions (Ca²⁺, Mg²⁺). Dosing system injects anti-scalant to prevent scale. For high silica or complex water, dosing is more effective. For very high hardness, a softener may still be needed.

7. What voltage is required?
Standard 380V / 50Hz (3-phase). 220V / 60Hz is available upon request.

8. How much floor space is required?
Approximately 8-10 square meters, including tanks, frame, and operation/maintenance access.

9. How long does installation take?
About 4-6 hours for the main system. Tank connections may take additional time. The system comes pre-assembled — just connect water inlet, drain, and power.

10. What is the MOQ?
1 set. OEM customization available for bulk orders.

Why Buy From Us?

✅ Factory Direct✅ CE Certified✅ 1-Year Warranty
No middleman. Better price.Internationally certified.Peace of mind.
✅ OEM Available✅ 24/7 Support✅ Global Shipping
Custom logo, color, voltage.We’re here to help.Delivered worldwide.

GET IN TOUCH

Schedule a Visit

Scroll to Top